Evaluation of the Potential for Containment Bypass due to Steam Generator Tube Rupture in VVER-1000/V320 Reactor during Extended SBO sequence using SCDAP/RELAP5 code
Main Article Content
Abstract
A severe accident-induced of a Steam Generator (SG) tube releases radioactivity from the Reactor Coolant System (RCS) into the SG secondary coolant system from where it may escape to the environment through the pressure relief valves and an environmental release in this manner is called “Containment Bypass”. This study aims to evaluate the potential for “Containment Bypass” in VVER/V320 reactor during extended Station Blackout (SBO) scenarios that challenge the tubes by primarily involving a natural circulation of superheated steam inside the piping loop and then induce creep rupture tube failure. Assessments are made of SCDAP/RELAP5 code capabilities for predicting the plant behavior during an SBO event and estimates are made of the uncertainties associated with the SCDAP/RELAP5 predictions for key fluid and components condition and for the SG tube failure margins.
Article Details
Keywords
Containment Bypass, SBO, SCDAP/RELAP5
References
[2]. Design, Safety Technology and Operability Features of Advanced VVERs, OKB “GIDROPRESS’’, 2011.
[3]. S., Pylev. Assessment Study of RELAP5/MOD3.2 Based on the Kalinin NPP Unit-1 Stop of Feedwater Supply to the Steam Generator No. 4, NUREG/IA-0167, published by US NRC, 1999.
[4]. C.D., Fletcher et al. SCDAP/RELAP5 Thermal-Hydraulic Evaluations of the Potential for Containment Bypass During Extended Station Blackout Severe Accident Sequences in a Westinghouse Four-Loop PWR. NUREG/CR-6995, published by US NRC, 2010.
[5]. C. Allison et al., “SCDAP/RELAP5/MOD2 Code Manual”, Volume: I, II and III, NUREG/CR-5237, EGG-2555, June 1989.