Parallel radon and thoron measurements in mineral sand mining area of Ha Tinh province

Bui Dac Dung1, Trinh Van Giap1, Tibor Kovacs1, Tran Ngoc Toan1, Le Dinh Cuong1, Tran Khanh Minh1, Nguyen Huu Quyet1, Nguyen Van Khanh1
1 Institute for Nuclear Science and Technology 179 - Hoang Quoc Viet, Nghia Do - Cau Giay, Ha Noi

Main Article Content

Abstract

In this study, we have tested the possibility of parallel measurement of radon (222Rn) and thoron (220Rn or Tn) by alpha track detectors at the extraction and processing of black sands that contains high content of Zircon and Monazite minerals in a coastal area of the Ha Tinh province. A pair of cylindrical cups RADUET, designed to separately measure Rn and Tn with CR-39 detectors (Radosys Company Ltd – Hungary), were used for the test. The results showed that concentrations of indoor Rn and Tn in the black sand extraction area are not high (28 ± 6 Bq/m3 for Rn, 14 ± 5 Bq/m3 for Tn). The Rn and Tn concentrations in the indoor air of the titanium processing plant are 34 ± 6 Bq/m3 for Rn, 58 ± 11 Bq/m3 for Tn, and are higher than those concentrations in the residential houses outside the plant (20 ± 4 Bq/m3 for Rn, 16 ± 8 Bq/m3 for Tn) but still comparable to the average concentrations of indoor Rn and Tn reported by the UNSCEAR 2006. At Zircon processing plant, indoor Rn concentrations are similar to those in the titanium processing plant but Tn concentrations in the houses for separating Rutile and Zircon are very high. Indoor Tn concentration is especially high in the house for separating Zircon where it could reach 2931 Bq/m3, hundred times higher than that in the surrounding residential houses and that of the world average published by UNSCEAR 2006.

Article Details

References

[1] International Atomic Energy Agency, “Extent of Environmental Contamination by Naturally
Occurring Radioactive Material (NORM) and Technological Options for Mitigation”, Technical Reports Series No. 419, STI/DOC/010/419 (ISBN: 9201125038) 2003.
[2] International Commission on Radiological Protection (ICRP), “ICRP Publication 66”, 1994.
[3] S. Tokonami, “Summary of dosimetry (radon and thoron) studies”, International Congress
Series 1276, Elsevier, 2005, pp. 151– 154.
[4] International Atomic Energy Agency, International Labour Office, “Occupational Radiation Protection in the Mining and Processing of Raw Materials”, Safety Standards Series No.RS-G-1.6, IAEA, Vienna, 2004.
[5] CEI/IEC 61577-1, “Radiation protection instrumentation - Radon and radon decay product measuring instruments – Part 1: General requirements”, 2000.
[6] CEI/IEC 61577-2, “Radiation protection instrumentation - Radon and radon decay product measuring instruments – Part 2: Specific requirements for radon measuring instruments”, 2000.
[7] MITRACO HATINH: Report on Titanium advanced processing technology (in Vietnamese), Company report, 2003.
[8] RADOSYS, “User Manual RS_Man63- 080316”, 2008.
[9] UNSCEAR Report Volume II, “Annex E: Sources-to-effects assessment for Rn in homes and workplaces”, 2006.